  "id": "1989_generator_reliability",
  "source_year": 1989,
  "paper_page": 1239,
  "source_table": "II",
  "verification": "review transcription from v0.2; independent validation pending",
  "notes": "",
  "records": [
    {
      "capacity_MW": 5,
      "technology": "hydro",
      "unit_count": 2,
      "FOR": 0.01,
      "MTTF_hours": 4380,
      "failure_rate_per_year": 2,
      "MTTR_hours": 45,
      "repair_rate_per_year": 198,
      "maintenance_weeks_per_year": 2
    },
    {
      "capacity_MW": 10,
      "technology": "thermal",
      "unit_count": 1,
      "FOR": 0.02,
      "MTTF_hours": 2190,
      "failure_rate_per_year": 4,
      "MTTR_hours": 45,
      "repair_rate_per_year": 196,
      "maintenance_weeks_per_year": 2
    },
    {
      "capacity_MW": 20,
      "technology": "hydro",
      "unit_count": 4,
      "FOR": 0.015,
      "MTTF_hours": 3650,
      "failure_rate_per_year": 2.4,
      "MTTR_hours": 55,
      "repair_rate_per_year": 157.6,
      "maintenance_weeks_per_year": 2
    },
    {
      "capacity_MW": 20,
      "technology": "thermal",
      "unit_count": 1,
      "FOR": 0.025,
      "MTTF_hours": 1752,
      "failure_rate_per_year": 5,
      "MTTR_hours": 45,
      "repair_rate_per_year": 195,
      "maintenance_weeks_per_year": 2
    },
    {
      "capacity_MW": 40,
      "technology": "hydro",
      "unit_count": 1,
      "FOR": 0.02,
      "MTTF_hours": 2920,
      "failure_rate_per_year": 3,
      "MTTR_hours": 60,
      "repair_rate_per_year": 147,
      "maintenance_weeks_per_year": 2
    },
    {
      "capacity_MW": 40,
      "technology": "thermal",
      "unit_count": 2,
      "FOR": 0.03,
      "MTTF_hours": 1460,
      "failure_rate_per_year": 6,
      "MTTR_hours": 45,
      "repair_rate_per_year": 194,
      "maintenance_weeks_per_year": 2
    }
  ]
}